Brand (A)KVVG, (A)KVVGE, (A)KVBbShv, (A)KVBShv, (A)KVKShv, (A)KPvVGE, (A)KPvBbShv, (A)KPvBShv, (A)KPvKShv, (A)KVBShp, (A)KVKShp, (A)KPvBShp, (A)KPvKShp

Brand (A)KVVG, (A)KVVGE, (A)KVBbShv, (A)KVBShv, (A)KVKShv, (A)KPvVGE, (A)KPvBbShv, (A)KPvBShv, (A)KPvKShv, (A)KVBShp, (A)KVKShp, (A)KPvBShp, (A)KPvKShp
Brand (A)KVVG, (A)KVVGE, (A)KVBbShv, (A)KVBShv, (A)KVKShv, (A)KPvVGE, (A)KPvBbShv, (A)KPvBShv, (A)KPvKShv, (A)KVBShp, (A)KVKShp, (A)KPvBShp, (A)KPvKShp

Control cables. Brand (A)KVVG, (A)KVVGE, (A)KVBbShv, (A)KVBShv, (A)KVKShv, (A)KPvVGE, (A)KPvBbShv, (A)KPvBShv, (A)KPvKShv, (A)KVBShp, (A)KVKShp, (A)KPvBShp, (A)KPvKShp

 

Cables are designed for installation in rooms, channels, tunnels, in an aggressive environment, in the absence of mechanical influences on the cable. Laying in the ground (trenches) is allowed while ensuring the protection of cables at the points of access to the surface. 
Fire hazard class according to ГОСТ 31565-2012 01.8.2.5.4 

 

Standard

GOST 1508-78

 

Main design elements

1. Single round core:

- Material:

Aluminum (AI)
- number of conductors 4; 5; 7; 10; 14; 19; 27; 37; 52; 61; -2.5 mm2
- number of conductors 4; 5; 7; 10; 14; - (4-10) mm2
Copper (Cu)
- number of conductors 4; 5; 7; 10; 14; 19; 27; 37; 52; 61; -2.5 mm2
-number of TPZ 4; 5; 7; 10; 14; - (4-10) mm2

 

2. Insulation:

-Polyvinylchloride (В);
-Cross-linked polyethylene (Пв).

3. Inner filling (belt insulation):

- for cables (A) KVVG made of PVC plastic;
- for cables with armor or screen (A) KVVGE, (A) KVBbShv, (A) KVBShv, (A) KVKShv, (A) KPVVGE, (A) KPvBbShv, (A) KPvBShv, (A) KPvKShv, (A) KVBShp, (A) KVKShp, (A) KPvBShp, (A) KPVKShp - made of PVC plastic or applied by winding or longitudinally with tapes made of polyvinyl chloride plastic.

 

*. Screen:

-for KVVGE, KPVVGE double copper tape, or overlap aluminum foil, copper wire along the foil. 

 

4. Armor:

- for cables (A)KVBbShv, (A)KVBShv, (A)KPvBbShv, (A)KPvBShv, (A)KVBShp, (A)KPvBShp, - double steel tape
- for cables (A)KVKShv, (A)KVKShv, (A)KVKShp, (A)KPvKShp - steel wires.

 

5. Outer sheath:

-Polyvinylchloride (В)
-Polyethylene (П)

 

Cable brand KVVG, AKVVG, KPVVG, AKPVVG

Control cable with insulation made of PVC plastic (B) or cross-linked polyethylene (PV) and a sheath made of PVC plastic, without a protective cover

 

Cable brand KVVGE, AKVVGE, KPVVGE, AKPVVGE

With a common screen made of aluminum or copper foil, with a sheath made of polyvinyl chloride plastic

 

Main area of ​​application

Cables are intended for installation in rooms, channels, tunnels, in aggressive environments, in the absence of mechanical impacts on the cable. Installation in the ground (trenches) is allowed, providing protection for cables at the points of exit to the surface. Fire hazard class according to GOST 31565-2012 01.B.2.5.4

 

Cable brand KVVGz, AKVVGz

With a sheath made of polyvinyl chloride plastic with filling

 

Main area of ​​application

Cables are intended for electrical installations requiring sealing when entering electrical equipment. Fire hazard class according to GOST 31565-2012 01.B.2.5.4

 

Cable brand KVBbShv, KVBShv, AKVBbShv, AKVBShv, KPvBbShv, KPvBShv, AKPvBbShv, AKPvBShv, KVKShv, AKVKShv, KVKShp, AKVKShp, KPvKShv, AKPvKShv, KPvKShp, AKPvKShp, KPvKaShv, AKPvKaShv, KPvKaShp, AKPvKaShp, KVKaShv, AKVKaShv, KVKaShp, AKVKaShp

With a protective cover of two steel tapes, with a protective hose, made of polyvinyl chloride plastic

Main area of ​​application

Cables are intended for installation in rooms, channels, tunnels, in aggressive environments, and in places exposed to stray currents, if the cable is not subjected to significant stretching forces and mechanical damage during operation. Fire hazard class according to GOST 31565-2012 01.B.2.5.4 (for cables with PVC sheath) and 02.B.2.5.4 (for cables with PE sheath).

 

Cable brand KVKShv, AKVKShv, KVKaShv, AKVKaShv, KPVKShv, AKPvKShv, KPVKaShv, AKPvKaShv

With a protective covering of round galvanized or aluminum, or aluminum alloy wires, with a protective hose made of polyvinyl chloride plastic

 

Main area of ​​application

The cables are intended for installations in rooms, channels, tunnels, in aggressive environments and in places where tensile forces are possible during operation. Fire hazard class according to GOST 31565-2012 01.B.2.5.4 (for cables with PVC sheath) and 02.B.2.5.4 (for cables with PE sheath).