Brand (A)KVVGng(A), KPvVGng(A), (A)KVVGEng(A), (A)KVBbShvng(A), (A)KVBShvng(A), (A)KVKShvng(A), (A)KPvVGEng (A), (A)KPvBbShvng(A), (A)KPvBShvng(A), (A)KPvKShvng(A)

Brand (A)KVVGng(A), KPvVGng(A), (A)KVVGEng(A), (A)KVBbShvng(A), (A)KVBShvng(A), (A)KVKShvng(A), (A)KPvVGEng (A), (A)KPvBbShvng(A), (A)KPvBShvng(A), (A)KPvKShvng(A)
Brand (A)KVVGng(A), KPvVGng(A), (A)KVVGEng(A), (A)KVBbShvng(A), (A)KVBShvng(A), (A)KVKShvng(A), (A)KPvVGEng (A), (A)KPvBbShvng(A), (A)KPvBShvng(A), (A)KPvKShvng(A)

Control cables. Brand (A)KVVGng(A), KPvVGng(A), (A)KVVGEng(A), (A)KVBbShvng(A), (A)KVBShvng(A), (A)KVKShvng(A), (A)KPvVGEng (A), (A)KPvBbShvng(A), (A)KPvBShvng(A), (A)KPvKShvng(A)

 

Cables with sheath made of polyvinyl chloride plastic compound of reduced flammability. Designed for fixed connection to electrical instruments, devices, clamp assemblies of electrical distribution devices with rated alternating voltage up to 0.66 kV, frequency up to 100 Hz or direct voltage up to 1 kV

 

Standard

GOST 1508-78

 

Main design elements

1. Single round core:

- Material:

Aluminum (AI)
- number of conductors 4; 5; 7; 10; 14; 19; 27; 37; 52; 61 ; -2.5 mm2
-number of TPG 4; 5; 7; 10; 14; - (4-10) mm2
Copper (Cu)
-amount of TPG 4; 5; 7; 10; 14; 19; 27; 37; 52; 61; -2.5 mm2
-number of TPG 4; 5; 7; 10; 14; - (4-10) mm2

 

2. Insulation:

-Polyvinylchloride (В);
-Cross-linked polyethylene (Пв)

 

3. Filler (Inner covering):

- for cables (A) KVVGng(A), KPVVGng(A) made of low-flammability PVC;
- for cables with armor or screen (A) KVVGEng (A), (A)KVBbShvng(A), (A)KVBShvng(A), (A)KVKShvng(A), (A)KPVVGEng(A), (A)KPVBbShvng(A), (A )KPvBShvng(A), (A)KPvKShvng(A), - made of PVC plastic with low flammability

 

*. Screen:

-for cables KVVGEng(A), KPVVGEng(A) double copper tape, or overlap aluminum foil, copper wire along the foil.

 

4. Armor:

- for cables (A)KVBbShvng(A), (A)KVBShvng(A), (A)KPvBbShvng(A), (A)KPvBShvng(A) - double galavanized steel tape; 
- for cables (A)KVKShvng(A), (A)KPvKShvng(A) - galvanized steel wires.

 

5. Outer sheath:

-Flame retardant PVC (В)

 

Cable brand KVVGng, AKVVGng, KVVGng(A), KPVVGng, KPVVGng( A)

Control cable with insulation made of polyvinyl chloride plastic(B) or cross-linked polyethylene(Пв) and a sheath flame retardant polyvinyl chloride plastic

 

Brand cables KVVGEng(A), KPVVGEng(A)

Copper screnn and filler, a sheath flame retardant polyvinyl chloride plastic

 

Main area of ​​application

Cables are designed for electrical installations that require sealing during insertion. Cables are used for laying in cable structures and premises to ensure fire safety of cable circuits when laying in bundles.
Fire hazard class according to ГОСТ 31565-2012 P16.8.2.5.4 classification

 

Cable brand KVVGzng, AKVVGzng

Steel tape armoured and a sheath flame retardant polyvinyl chloride plastic

 

Main area of ​​application

Cables are intended for installation in rooms, channels, tunnels, in aggressive environments, and in places exposed to stray currents, if the cable is not subjected to significant tensile forces and mechanical damage during operation. 
Fire hazard class according to ГОСТ 31565-2012 P16.8.2.5.4 classification

 

Cable brand KVBbShvng, KVBShvng(A)

Aluminum or aluminum alloy wire armoured and a sheath flame retardant polyvinyl chloride plastic

Main area of ​​application

Cables are intended for installation in rooms, channels, tunnels, in aggressive environments, and in places exposed to stray currents, if the cable is not subjected to significant tensile forces and mechanical damage during operation. 
Fire hazard class according to ГОСТ 31565-2012 P16.8.2.5.4 classification

 

Cable brand KVKShvng(A), KVKaShv(A)

Cables are designed for installation in rooms, channels, tunnels, in aggressive environments and in places where tensile forces are possible during operation.
Fire hazard class according to ГОСТ 31565-2012 P16.8.2.5.4 classification

 

Main area of ​​application

Cables are designed for installation in rooms, channels, tunnels, in aggressive environments and in places where tensile forces are possible during operation.
Fire hazard class according to ГОСТ 31565-2012 P16.8.2.5.4 classification